Le2000

HOT

200-2000 mL/min

Constant flow air Sampling Pumps

Product name:Constant flow air Sampling Pumps

Model:Le2000

Manufacturer:GongLe 

The Le 2000 constant flow air Sampling Pumps can be applied to laboratory gas release chambers, indoor environments, public health, occupational health, and other scenarios to collect and detect gaseous pollutants in the air. It can be connected to various sampling media such as solid adsorbent tubes, bubble absorption tubes, filter material sampling clips, etc., to collect gases, dust, particulate matter, etc. in the air, in order to detect toxic substances.

Video

The Le2000 constant flow air Sampling Pumps is a portable sampling device with a flow range of 100-1600 milliliters per minute, which complies with the provisions of JJF1404-2013 "Outline for Evaluation of Atmospheric Sampling Pumps Types" and JJG956-2013  "Verification Regulations for Atmospheric Sampling Pumpss".

The Le2000 constant current air Sampling Pumps adopts the advancedclosed-loop intelligent control system LeAiOS, achieving precise and stable constant current sampling.

This device is equipped with a color touch screen and excellent UI human-computer interaction design, which can achieve various sampling modes such as manual/timing/constant volume/programming. At the same time, it can also monitor flow, sampling volume, temperature, and pressure indicators in real-time, and will automatically alarm in case of errors.

In addition, it can calculate and record corresponding average values and STP standard volume data.

It has a compact body, long endurance, and can withstand a back pressure of up to 35kPa, meeting the requirements of various sampling specifications. It is suitable for various air sampling occasions such as personal, fixed point, and laboratory applications.

Functional Characteristics


 

Cconstant-current control

The Le 2000 constant flow air Sampling Pumps adopts the advanced LeAiOS closed-loop intelligent control system, which can accurately control the constant airflow and maintain extremely high stability, ensuring that the flow error is within ± 5%

 

Error Recovery

When the sampled flow exceeds the deviation range or the gas path is blocked, the LED light will issue an error reminder and record the error time. At the same time, the system will automatically adjust the sampling flow rate and withstand voltage capacity, or perform intermittent restarts for recovery. 

Back pressure compensation

Real time detection of changes in sampling resistance to compensate for sampling flow, with a maximum load of 35 kPa.

 

Sampling program

Flexible sampling program settings and selection, manual, timed, constant volume, and programming.

STP volume

Built in high-precision temperature and pressure compensation system for correcting air capacity and calculating STP standard volume.

 

Extra Long Range

High energy density rechargeable batteries ensure long-term battery life of the instrument.

Flow calibration

Digital calibration, automatic load resistance calibration memory function.

 

Sturdy and safe

The system has a sturdy and safe protection level of IP65, is equipped with a system safety lock, and has intrinsic safety explosion-proof certification 

Color touch screen

LED color touch screen, excellent UI human-machine interaction design, simple and convenient operation.

 

Excellent design

Ergonomic design, lightweight and portable, anti slip and impact resistant, comfortable to wear.

Display Interface


Run interface


Data record


Sampling programming


Main menu interface

Technical Specifications

Constant flow range200 - 2000 mL/min
Constant pressure flow range1 - 2000 mL/min optional constant pressure multi tube sampling device
Constant flow rate error< + 5% of the set flow rate
Load capacityMaximum load 35kPa, typical 35 kPa @ 500 mL/min
Storage999 sets, recording each sampling information for easy traceability
Battery packRechargeable battery pack, fully charged within 3 hours, with overcharge and discharge function
Run time20 hours (typical 500 mL/min @ 4.5 Kpa)
Measurement displayReal time flow (Flow), Sampling time (RT), Sampling volume (VT), Back pressure (BP), Temperature (T), Error time (FT)Estimated stop time (ET), Operating mode, Power Date, Time, Data file
Operating modeManual, Constant volume, Timing, Sampling programming, Flow setting,Specified start time, Delay time, Sampling cycletime, Pause time, and number of cycles
Sampling calculationAverage sampling flow rate, Sampling volume, STP standard volume
Flow calibrationDigital calibration, Automatic load resistance calibration memory function
LED indicator lightGreen and red lights, Fast and slow flashing, lndicating normal operation,lncorrect flow rate, Charqing status, Etc
Specification
ATEXIntrinsically safe explosion-proof
Protection gradeIP65
LanguageChinese, English optional
Display screenTouch color display screen
Control keys1 physical Home key, Touch screen button
Work noise<48.1 dBA
Work environmentTemperature -10~50C, humidity 0~95% non condensing
Tolerance
  • Vibrate 4Hz@30m/s,2h
  • lmpact 500 m/s@ (11+1) ms (GB/T 2423.5-1995)
  • Drop 1m (GBT 2423.8-1995)
Size100 × 97 × 50 mm
Weight457 g
Base adapter
  • Single unit group, Three unit group, Five unit group
  • Charging and connection interface, LED indicator light
  • Input voltage: 220 VAC / 50 Hz

Our company's policy is to continuously innovate and develop our products.

Therefore, we reserve the right to change product specifications without prior notice.

Application

* We regularly send the latest product information to your email.